RICE LAKE Ranger 1 Variable Range Simulator
May 13, 2019RICE LAKE Transducer Simulator 4
May 13, 2019RICE LAKE Ranger 3 Variable Range Simulator
- ABS plastic case, weighs less than 1 lb
- Fixed rotary switch, -0.5 mV/V to 4.5 mV/V in nine steps of 0.5mV/V per step
- Ideal tool for calibrating the indicator A-D offset and gain setting
- A-D calibration steps for -0.5 mV/V for offset and 4.5 mV/V for gain
- Used in testing, troubleshooting and calibrating digital weight indicators
- Binding posts are color coded to ISA S37.8 standard
Information
The Ranger 3 variable range simulator is well suited for calibration needs, offering nine fixed intervals from -5 mV/V to +4.5 mV/V.
Ranger 3 Variable Range Simulator Specifications
Range: Impedance: Nonlinearity: Connectors: Temperature Coefficient: Dimensions: Warranty:
-0.5 mV/V-4.5 mV/V range
350 ohm nominal
Less than 0.02%
Binding posts suitable for banana plug or
14-gauge wire
±5 ppm/ °C
(W x L x H) 4.5 in x 3.5 in x 1.25 in (114.3 mm x 88.9 mm x 31.8 mm)
One-year limited warranty