RICE LAKE JB1010ST Signal Trim Junction Box
May 13, 2019RICE LAKE TP75 DC Transient Protector
May 13, 2019RICE LAKE iQUBE²® Digital Diagnostic Junction Box
Applications
- Truck and railroad scales
- Tank and hopper scales
- Multi-channel scales
- Interfaces to 920i®, 1280, VIRTUi2® and ASCII serial commands
Information
iQUBE²® is leading a new generation of digital junction boxes. At the forefront of iQUBE²’s cutting edge design are enhanced features that will redefine expectations for traditional analog to digital technology.
For mission-critical applications and unmatched performance, iQUBE² is the equipment of choice. Its high-speed ability to update up to 500 times per second on multi-channels makes it the fastest smart junction box available. Unmatched reaction time brings accuracy to new levels, increasing precision and profits.
Enhanced onboard diagnostics will identify noise, test for linearity and zero reference, and monitor drift. Diagnostics are enhanced by a unique load cell emulation feature which compensates for a failing load cell until a repair can be made.
iQUBE² Digital Diagnostic Junction Box Dimensions
Dimensions | |||
---|---|---|---|
Stainless Steel 8 x 10 in | |||
A | 8.91 in (226.3 mm) | E | 11.50 in (292.1 mm) |
B | 10.13 in (257.3 mm) | F | 10.75 in (268.5 mm) |
C | 12.57 in (319.3 mm) | G | 6.00 in (152.4 mm) |
D | 4.29 in (109 mm) | H | 0.312 in (7.9 mm) |
FRP Large 10 x 12 in | |||
A | 11.30 in (287 mm) | E | 13.53 in (343.7 mm) |
B | 13.33 in (338.6 mm) | F | 12.76 in (324.1 mm) |
C | 14.00 in (355.6 mm) | G | 8.00 in (203.2 mm) |
D | 5.57 in (141.5 mm) | H | 0.312 in (7.9 mm) |
FRP Small 8 in x 10 in | |||
A | 9.31 in (236.5 mm) | E | 11.51 in (287.2 mm) |
B | 11.31 in (287.2 mm) | F | 10.75 in (273.1 mm) |
C | 12.85 in (326.4 mm) | G | 6.00 in (152.4 mm) |
D | 5.42 in (137.7 mm) | H | 0.312 in (7.9 mm) |
iQUBE² Digital Diagnostic Junction Box Specifications
Voltage Input: Load Cell Inputs: A/D Sampling Rate:
Stainless steel or Fiberglass Reinforced Polyester (FRP), NEMA Type 4X enclosure
115/230 V AC power supply DC/DC converter for 9-36V
6-12 V DC to CPU
Four channels per board up to four networked boards
2.5-500 Hz (selectable)
Analog signal sensitivity: Load Cell Excitation: Analog range:
14°F to 104°F (-10°C to 40°C)
0.3 uV/grad at 30 Hz
0.5 uV/grad at 100 Hz
1.2 uV/grad at 500 Hz
5 V DC, 57 mA maximum per channel
-4.5 mV/V to 4.5 mV/V
Warranty:
NTEP 03-032A1
Measurement Canada – AM-5561, Rev. 1
UL E151461
CE
Two-year limited warranty